Philips xl30 sem user manual

Fei philips xl 30 field emission esem the xl 30 esem combines a highbrightness feg source with a conventional electron column. This xl30 also equipped with eds detector to provide the composition information. Philips hd11 xe getting started manual 278 pages ultrasound system. The upper group of controls allow the user to choose the scan rate. Then you can save the image as a tiff or jpeg image in the xl30 shared data folder on desktop. About this electronic users manual about this guide other documents you may need notational descriptions about this guide this electronic users guide is intended for anyone who uses the philips 150b lcd monitor. Need a manual for your philips hd9240 avance collection airfryer xl deep fryer. See sem philips xl30 manual pdf for detailed operation procedures. The fieldemission electron source feg and hexalens electron column are capable of imaging resolution down to 1. Forensic use of philips xl 30 esem vojin mastruko forensic centre of ministry of interior, zagreb, croatia abstract. Thermo scientific introduces quattro sem for materials science, an ultraversatile highresolution. Philips heartstart xl plus owners manual aed superstore. Manual philips hd9240 avance collection airfryer xl deep. Fei xl30 sfeg highresolution scanning electron microscope the xl30 sfeg is a highresolution scanning electron microscope capable of resolutions better than 2 nm, magnifications over 600 kx, and operating voltages from 200 volts up to 30 kv with 1 kv and 2 kv being routine.

Visit the support page for your philips shaver series 5000. C load a sample and evacuate the chamber c obtain an electron beam c obtain a secondary electron image c learn to focus. Log on using username semuser and password semuser. Philips af 877 owners manual, service manuals and schematics are for reference only and the vinyl engine bears no responsibility for errors or other inaccuracies. Fei philips xl30 feg esem, with electron backscatter diffraction analysis and energydispersive xray capability esem images from philips electron optics this microscope is a high performance, extremely flexible and wellequipped microscope for general purpose microscopy, lowvacuum and environmental scanning microscopy esem, and electron. Xl30 image display to the screen on the right side. Philips xl30 feg sem with edax eds system is a thermionic field emission sem which is fully automatic gun configuration controlled by advanced computer technology. Fei philips xl 30 feg sem operation procedure before using the microscope, first you should use your assigned username and password to login to the microscope control system located down in the hall way. It is assumed that the instrument has been started up. Philips electron optics xl30 sem scanning electron microscope set up with detectors for energydispersive xray spectroscopy edx or edax pw 663005 9432 066 30001. By specifying your reason for contact we will be able to provide you with a better service. The xl 30 offers a 4 axis motorized stage with full manual override.

Philips xl 40 esem electron optics facility michigan. Highperformance electron microscopy workflow solutions fei. Philips xl cordless phone with answering machine xl6651c 6000series champagne 43 pages cordless telephone philips xl6601c38 user manual. The philips feg sem handbook this section adapted from the philips user manual chapter 4 this chapter describes the basic operation of the microscope, involving several steps to achieve hardcopy results or image transfers to disk. The xl30 is a conventional sem with optimum performance for both imaging and microanalysis of conductive andor coated specimens. General operating procedures january 14 th16 follow the directions listed under general operating procedures for the philips xl30 sem. Unlike conventional sems which require high vacuum in the specimen chamber, the microscope can be run in a highpressure environmental mode allowing the examination of hydrated or insulating samples. Fei xl30sfeg highresolution scanning electron microscope the xl30sfeg is a highresolution scanning electron microscope capable of resolutions better than 2 nm, magnifications over 600 kx, and operating voltages from 200 volts up to 30 kv with 1 kv and 2 kv being routine. Diagram the problem is my hometheater having a sho. Advanced accessories include a thinwindow energy dispersive spectrometer eds and hot or cold stages. This information is subject to change without notice.

Since late 1998, sem has been installed in forensic centre, zagreb, croatia. After tv, the fastest is slow scan 1, the slowest is slow scan 3. This makes the system ideal for dedicated research in metallography as. User manual instruction guide for philips devices philips user manuals philips china investment co. We have 1 philips hd11 xe manual available for free pdf download. There are also frequently asked questions, a product rating and feedback from users to. Enclosures for protection against the high voltages of the sem power supply e. Artist getty images music 483618, getty images music 483619, getty images music 483622, getty images music 483623. If the images are saved correctly in the shared data folder on sem computer, you should. Below you can view and download the pdf manual for free. Feiphilips xl30 field emission esem the xl30 esem combines a highbrightness feg source with a conventional electron column. View and download philips xl300 user manual online. User manual instruction guides for philips devices.

To obtain a single frame at slow scan 3, press the f2 key on the keyboard at any time. Hitachi regulus 8230 feg sem is an ultra high resolution sem installed in imri mc2 facililty 140b et in june 2019 gatan camera upgrade 20190407. Philips environmental scanning electron microscope esem xl 30 with edax edxdetector and philips gsr nt v. Reproduction without prior permission or for financial gain is strictly prohibited. Philips 7000 series 47pfl7008 3d ultraslim smart led tv user manual. In this page you find schematic, users and instructions manuals, service manuals, technical supplement, leaf leads and other good stuff. All the quanta sem systems can be equipped with analytical systems, such as energy dispersive spectrometer, wavelength dispersive xray spectroscopy and electron backscatter diffraction. Samples can be examined in an atmosphere of up to 10 torr of water vapour, oxygen, nitrogen carbon dioxide. Philips hd9240 avance collection airfryer xl deep fryer.

It is easy to use for examining and survey the morphology of the nano devices. The philips xl30 sem operation procedure this section adapted from the philips user manual chapter 4, for detail, please refer to the user manual this chapter describes the basic page 527. Feiphilips sirion field emission sem the fei sirion scanning electron microscope sem is a highresolution instrument with an electron beam voltage range from 200v 30kv. Philips flat tv with crystal clear 20 lcd 20pf4121 turn up your viewing experience with crystal clear here is an lcd tv that not only enhances the decor of your home with its european styling and slim design, but also provides a great audiovisual experience with crystal clear and virtual dolby surround. The philips fei xl30 esem environmental scanning electron microscope can perform high vacuum, low vacuum and wet modes imaging from 1kv30kv and 10x100,000x magnification. Its maximum resolution under optimal conditions is 3. The intellivue mx40 wearable patient monitor gives you technology, intelligent design, and innovative features you expect from philips in a device light enough and small enough to be comfortably worn by ambulatory patients. This system provides both secondary electron and backscattered electron imaging, along with an integrated edax system. It can be used for conventional high vacuum imaging, or in the environmental mode, can be used to examine wet, oily, gassy or nonconducting samples. The fei philips xl 40 environmental scanning microscope is a large chamber scanning electron microscope capable of imaging hydrated and contaminated samples.

The philips xl30 sem handbook hong kong university of. Philips fei xl30 sem edax xray analysis scanning electron. Operating voltage should be set to 15kev or higher and a spot size of 4 or 5 is recommended. The philips xl 30 is a conventional sem with mousedriven operation in a windows environment. If you have some stuff that not is listed here you can donate this by contact mods. Philips makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. The online information center help provides a quick guide for completing basic tasks and troubleshooting problems. The magnification is up to 800,000x with 2nm resolution.

The philips xl30 esem is a flexible scanning electron microscope with a large chamber. Framemaker is a registered trademark of adobe systems incorporated. The philipsfei xl30 esem environmental scanning electron microscope can perform high vacuum, low vacuum and wet modes imaging from 1kv30kv and 10x100,000x magnification. Find the appropriate categories of philips products. Philips fei xl30 feg sem with edax eds complete system. Intellivue patient monitor franks hospital workshop. There are also frequently asked questions, a product rating and feedback from users to enable you to optimally use your product.

Feiphilips xl30 feg esem, with electron backscatter diffraction analysis and energydispersive xray capability esem images from philips electron optics this microscope is a high performance, extremely flexible and wellequipped microscope for general purpose microscopy, lowvacuum and environmental scanning microscopy esem, and electron. Philips shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The online quick guide also provides user information for the philips telemetry system. It describes the lcd monitors features, setup, operation and other pertinent information. The xl30 is the conventional scanning electron microscope of the xl series from philips and is suitable for a wide variety of applications. Thermo scientific introduces prisma e sem for materials science, the most complete sem for multiuser laboratories requiring allround performance and easeofuse. Trademark acknowledgments excel is a registered trademark of microsoft corporation. Failure to observe a caution may result in minor or. The philips xl30 sem operation procedure this section adapted from the philips user manual chapter 4, for detail, please refer to the user manual this chapter describes the basic operation of the microscope, involving several steps to achieve hardcopy results or image transfers to disk. Anton paar tosca 400 afm has been installed in imri mc2 facility 140 et on 6252019 hitachi regulus 8230 ultra high resolution sem 20190620 12.

1104 1460 329 1094 618 572 606 1451 1082 1337 160 1237 1243 620 824 433 1151 264 1503 210 1053 23 572 339 1006 301 1278 990 1427 407 950 1459 1242 576 1401 1345 1016 584 541 461 103 781 155